I-2P 4Pole 40A 63A 30mA B Uhlobo lwe-RCD DC 6mA I-Residual Current Earth Leakage Circuit Breaker
1.Inikeza isivikelo ngokumelene nephutha lomhlaba / ukuvuza kwamanje kanye nomsebenzi wokuzihlukanisa.
2. Umthamo wokumelana nomthamo wamanje we-short-circuit wamanje.
3. Isebenza kutheminali kanye noxhumano lwebha yebhasi yephini/imfoloko.
| Into | Uhlobo B RCD/ Uhlobo B RCCB |
| Imodeli Yomkhiqizo | I-MIDA-100B |
| Uhlobo | B Uhlobo |
| Ikalwe okwamanje | 16A , 25A , 32A , 40A , 63A , 80A ,100A |
| Izigxobo | 2Pole ( 1P+N), 4Pole ( 3P+N ) |
| I-voltage elinganiselwe i-Ue | 2Isigxobo: 240V ~, 4Isigxobo: 415V~ |
| I-Insulation Voltage | 500V |
| Ikalwe imvamisa | 50/60Hz |
| Isilinganiso sokusebenza kwensalela yamanje(I n) | 30mA, 100mA, 300mA |
| I-Short-circuit current Inc= I c | 10000A |
| I-SCPD fuse | 10000 |
| Isikhathi sokuphumula ngaphansi kwe-I n | ≤0.1s |
| I-Dielectric test voltage ku-ind.Freq.okwe 1min | 2.5kV |
| Impilo kagesi | 2,000 Imijikelezo |
| Impilo yemishini | 4,000 Imijikelezo |
| Idigri Yokuvikela | IP20 |
| Izinga lokushisa le-ambient | -5℃ kufika ku +40℃ |
| Izinga lokushisa lesitoreji | -25℃ kufika ku +70℃ |
| Uhlobo lokuxhumeka kwetheminali | Ibha yebhasi yohlobo lwekhebula/Iphini U-uhlobo lwebhasi |
| Usayizi wetheminali phezulu/phansi kwekhebula | 25mm² 18-3AWG |
| Usayizi wetheminali phezulu/phansi kwebha yebhasi | 25mm² 18-3AWG |
| I-torque yokuqinisa | 2.5Nm 22In-Ibs |
| Ukukhweza | Ku-DIN ujantshi EN60715(35mm) ngedivayisi yokunamathisela esheshayo |
| Ukuxhumana | Kusukela phezulu naphansi |
| Okujwayelekile | I-IEC 61008-1:2010 EN 61008-1:2012 I-IEC 62423:2009 EN 62423:2012 |
Sengiphetha, i-RCCB noma i-RCD iyithuluzi lokuphepha elibalulekile elisiza ukuvikela abantu ekushayweni kukagesi okubangelwa imisinga eyinsalela.Uhlobo B RCD luyakhethwa kunoHlobo A RCD kuzilungiselelo zezimboni njengoba lunikeza ukuvikeleka okwengeziwe kumagagasi ayinsalela e-DC.Umehluko omkhulu phakathi kohlobo B nohlobo A yikhono lokubona ama-residual currents e-DC.Iningi lamafekthri eziteshi zokushaja akhetha Uhlobo B RCCB ukuze aqinisekise ukuphepha kwabasebenzi bawo.Ngakho-ke, kubalulekile ukuqonda umehluko phakathi kwezinhlobo ezimbili zama-RCCB futhi ukhethe efanelekile yokulungiselelwa kwakho, kuye ngamadivayisi asetshenziswayo.
Umehluko omkhulu phakathi kohlobo B no-A uhlobo lwe-RCD ukuhlolwa kwe-DC 6mA.Ama-currents ayinsalela e-DC ngokuvamile avela kumadivayisi aguqula i-AC abe yi-DC noma asebenzisa ibhethri.I-Type B RCD ithola la maza asalayo bese inqamula ugesi, ivikela abantu ekushayweni kukagesi.
Iningi lamafekthri eziteshi zokushaja akhetha Uhlobo B RCD, njengoba afakwe amadivayisi anikwa amandla yi-DC.Ezimbonini ezinjalo, ukuphepha kwezisebenzi kuyinto ehamba phambili, futhi Uhlobo lwe-B RCCB luyithuluzi elifanele lokuphepha elinikeza isivikelo kumaza asalayo.


























