isibhengezo_sekhanda

I-2P 4Pole 40A 63A 30mA B Uhlobo lwe-RCD DC 6mA I-Residual Current Earth Leakage Circuit Breaker

Incazelo emfushane:

Imodeli: MIDA-100B
Kukalwe Okwamanje: 16A, 25A,32A ,40A, 63A, 80A 100A
Izigxobo: 2Pole (1P+N), 4Pole (3P+N)
I-voltage elinganiselwe: 2Pole: 230V/240V, 4Pole: 400V/415V
Imvamisa elinganiselwe: 50/60Hz
Isilinganiso sokusebenza kwensalela yamanje:30mA ,100mA ,300mA
I-Short-circuit current Inc= I c 10000A
Okujwayelekile: IEC 61008-1 , IEC 62423
Uhlobo lwe-RCD B 40A 30mA DC 6mA kanye ne-RCCB Uhlobo B 63A 30mA DC 6mA
Thayipha i-B RCD 40A 4Pole 2Pole 30mA yesiteshi seshaja se-EV


Imininingwane Yomkhiqizo

Omaka bomkhiqizo

I-RCCB

1.Inikeza isivikelo ngokumelene nephutha lomhlaba / ukuvuza kwamanje kanye nomsebenzi wokuzihlukanisa.

2. Umthamo wokumelana nomthamo wamanje we-short-circuit wamanje.

3. Isebenza kutheminali kanye noxhumano lwebha yebhasi yephini/imfoloko.

Into Uhlobo B RCD/ Uhlobo B RCCB
Imodeli Yomkhiqizo I-MIDA-100B
Uhlobo B Uhlobo
Ikalwe okwamanje 16A , 25A , 32A , 40A , 63A , 80A ,100A
Izigxobo 2Pole ( 1P+N), 4Pole ( 3P+N )
I-voltage elinganiselwe i-Ue 2Isigxobo: 240V ~, 4Isigxobo: 415V~
I-Insulation Voltage 500V
Ikalwe imvamisa 50/60Hz
Isilinganiso sokusebenza kwensalela yamanje(I n) 30mA, 100mA, 300mA
I-Short-circuit current Inc= I c 10000A
I-SCPD fuse 10000
Isikhathi sokuphumula ngaphansi kwe-I n ≤0.1s
I-Dielectric test voltage ku-ind.Freq.okwe 1min 2.5kV
Impilo kagesi 2,000 Imijikelezo
Impilo yemishini 4,000 Imijikelezo
Idigri Yokuvikela IP20
Izinga lokushisa le-ambient -5℃ kufika ku +40℃
Izinga lokushisa lesitoreji -25℃ kufika ku +70℃
Uhlobo lokuxhumeka kwetheminali Ibha yebhasi yohlobo lwekhebula/Iphini
U-uhlobo lwebhasi
Usayizi wetheminali phezulu/phansi kwekhebula 25mm² 18-3AWG
Usayizi wetheminali phezulu/phansi kwebha yebhasi 25mm² 18-3AWG
I-torque yokuqinisa 2.5Nm 22In-Ibs
Ukukhweza Ku-DIN ujantshi EN60715(35mm)
ngedivayisi yokunamathisela esheshayo
Ukuxhumana Kusukela phezulu naphansi
Okujwayelekile I-IEC 61008-1:2010 EN 61008-1:2012
I-IEC 62423:2009 EN 62423:2012

Sengiphetha, i-RCCB noma i-RCD iyithuluzi lokuphepha elibalulekile elisiza ukuvikela abantu ekushayweni kukagesi okubangelwa imisinga eyinsalela.Uhlobo B RCD luyakhethwa kunoHlobo A RCD kuzilungiselelo zezimboni njengoba lunikeza ukuvikeleka okwengeziwe kumagagasi ayinsalela e-DC.Umehluko omkhulu phakathi kohlobo B nohlobo A yikhono lokubona ama-residual currents e-DC.Iningi lamafekthri eziteshi zokushaja akhetha Uhlobo B RCCB ukuze aqinisekise ukuphepha kwabasebenzi bawo.Ngakho-ke, kubalulekile ukuqonda umehluko phakathi kwezinhlobo ezimbili zama-RCCB futhi ukhethe efanelekile yokulungiselelwa kwakho, kuye ngamadivayisi asetshenziswayo.

I-RCCB

Umehluko omkhulu phakathi kohlobo B no-A uhlobo lwe-RCD ukuhlolwa kwe-DC 6mA.Ama-currents ayinsalela e-DC ngokuvamile avela kumadivayisi aguqula i-AC abe yi-DC noma asebenzisa ibhethri.I-Type B RCD ithola la maza asalayo bese inqamula ugesi, ivikela abantu ekushayweni kukagesi.

Iningi lamafekthri eziteshi zokushaja akhetha Uhlobo B RCD, njengoba afakwe amadivayisi anikwa amandla yi-DC.Ezimbonini ezinjalo, ukuphepha kwezisebenzi kuyinto ehamba phambili, futhi Uhlobo lwe-B RCCB luyithuluzi elifanele lokuphepha elinikeza isivikelo kumaza asalayo.

I-MIDA

  • Okwedlule:
  • Olandelayo:

  • Shiya Umlayezo Wakho:

    Bhala umyalezo wakho lapha futhi usithumelele wona
    • Silandele:
    • facebook
    • linkedin
    • i-twitter
    • youtube
    • i-instagram

    Shiya Umlayezo Wakho:

    Bhala umyalezo wakho lapha futhi usithumelele wona