isibhengezo_sekhanda

I-RCCB 4 Pole 40A 63A 80A 30mA Uhlobo B RCD Earth Leakage Circuit Breaker ye-DC 6mA EV Isiteshi sokushaja

Incazelo emfushane:

Imodeli: MIDA-100B
Kukalwe Okwamanje: 16A, 25A,32A ,40A, 63A, 80A 100A
Izigxobo: 2Pole (1P+N), 4Pole (3P+N)
I-voltage elinganiselwe: 2Pole: 230V/240V, 4Pole: 400V/415V
Imvamisa elinganiselwe: 50/60Hz
Isilinganiso sokusebenza kwensalela yamanje:30mA ,100mA ,300mA
I-Short-circuit current Inc= I c 10000A
Okujwayelekile: IEC 61008-1 , IEC 62423
Uhlobo lwe-RCD B 40A 30mA DC 6mA kanye ne-RCCB Uhlobo B 63A 30mA DC 6mA
Thayipha i-B RCD 40A 4Pole 2Pole 30mA yesiteshi seshaja se-EV


Imininingwane Yomkhiqizo

Omaka bomkhiqizo

I-RCCB (6)

I-Residual Current Circuit Breaker (RCCB) noma I-Residual Current Device (RCD) iyingxenye ebalulekile yesiteshi seshaja.Kuyithuluzi lokuphepha elisiza ukuvikela abantu ekushayweni kukagesi okubangelwa amandla asalayo.Ngenkathi usebenzisa izinto ezisebenza ngogesi, kungase kube namathuba okuvuza kwamanje ngenxa yesekhethi emfishane noma iphutha le-insulation.Ezimweni ezinjalo, i-RCCB noma i-RCD inqamula ukunikezwa kwamandla ngokushesha nje lapho ithola ukuvuza kwamanje, ngaleyo ndlela ivikela abantu kunoma iyiphi ingozi.

Into Uhlobo B RCD/ Uhlobo B RCCB
Imodeli Yomkhiqizo I-EKL6-100B
Uhlobo B Uhlobo
Ikalwe okwamanje 16A , 25A , 32A , 40A , 63A , 80A ,100A
Izigxobo 2Pole ( 1P+N), 4Pole ( 3P+N )
I-voltage elinganiselwe i-Ue 2Isigxobo: 240V ~, 4Isigxobo: 415V~
I-Insulation Voltage 500V
Ikalwe imvamisa 50/60Hz
Isilinganiso sokusebenza kwensalela yamanje(I n) 30mA, 100mA, 300mA
I-Short-circuit current Inc= I c 10000A
I-SCPD fuse 10000
Isikhathi sokuphumula ngaphansi kwe-I n ≤0.1s
I-Dielectric test voltage ku-ind.Freq.okwe 1min 2.5kV
Impilo kagesi 2,000 Imijikelezo
Impilo yemishini 4,000 Imijikelezo
Idigri Yokuvikela IP20
Izinga lokushisa le-ambient -5℃ kufika ku +40℃
Izinga lokushisa lesitoreji -25℃ kufika ku +70℃
Uhlobo lokuxhumeka kwetheminali Ibha yebhasi yohlobo lwekhebula/Iphini
U-uhlobo lwebhasi
Usayizi wetheminali phezulu/phansi kwekhebula 25mm² 18-3AWG
Usayizi wetheminali phezulu/phansi kwebha yebhasi 25mm² 18-3AWG
I-torque yokuqinisa 2.5Nm 22In-Ibs
Ukukhweza Ku-DIN ujantshi EN60715(35mm)
ngedivayisi yokunamathisela esheshayo
Ukuxhumana Kusukela phezulu naphansi
Okujwayelekile I-IEC 61008-1:2010 EN 61008-1:2012
I-IEC 62423:2009 EN
Impilo Yemishini I-plug In / Khipha Akulayishiwe >Izikhathi eziyi-10000
Izinga Lokushisa Lokusebenza -25°C ~ +55°C
Izinga Lokushisa Lokugcina -40°C ~ +80°C
Idigri Yokuvikela IP65
Usayizi Webhokisi Lokulawula le-EV 248mm (L) X 104mm (W) X 47mm (H)
Okujwayelekile I-IEC 62752, IEC 61851
Isitifiketi I-TUV, CE Igunyazwe
Ukuvikelwa 1.Over and under frequency protection
3.I-Leakage Current Protection (qala kabusha ukutakula)
5. Ukuvikela ukulayisha ngokweqile (ukuzihlola ukuthi uyalulama)
7.Over voltage kanye under-voltage ukuvikelwa
2. Ngaphezu Kokuvikela Kwamanje
4. Ukuvikelwa Ngokwezinga Lokushisa
6. I-Ground Protection kanye nokuvikelwa kwesekethe emfushane

I-IEC 62752:2016 isebenza kumadivayisi angaphakathi kwekhebula nokuvikela (IC-CPDs) ekushajweni kwemodi 2 yezimoto zomgwaqo ezisebenza ngogesi, ngemuva kwalokhu okubizwa nge-IC-CPD okuhlanganisa imisebenzi yokulawula nokuphepha.Leli zinga lisebenza kumadivayisi aphathekayo asebenza kanyekanye imisebenzi yokutholwa kwamandla asele, wokuqhathanisa inani lamanje nenani elisele lokusebenza kanye nokuvulwa kwesekethe evikelekile lapho amandla asele edlula leli nani.

I-RCCB

Ngokuyinhloko kunezinhlobo ezimbili zama-RCCB: Uhlobo B kanye Nohlobo A. Uhlobo A luvame ukusetshenziswa ezindlini, kuyilapho uhlobo B lukhethwa kuzilungiselelo zezimboni.Isizathu esiyinhloko ukuthi, Uhlobo B lunikeza ukuvikeleka okwengeziwe kumaza asele e-DC angawanikezi Uhlobo A.

Uhlobo B RCD lungcono kunoHlobo A njengoba lukwazi ukubona ama-currents ayinsalela e-DC aphansi njengo-6mA, kuyilapho u-A ungathola kuphela ama-residual currents e-AC.Kuzicelo zezimboni, ama-currents ensalela e-DC avame kakhulu ngenxa yokusetshenziswa kwemishini enamandla e-DC.Ngakho-ke, Uhlobo B RCD luyadingeka ezindaweni ezinjalo.

Umehluko omkhulu phakathi kohlobo B no-A uhlobo lwe-RCD ukuhlolwa kwe-DC 6mA.Ama-currents ayinsalela e-DC ngokuvamile avela kumadivayisi aguqula i-AC abe yi-DC noma asebenzisa ibhethri.I-Type B RCD ithola la maza asalayo bese inqamula ugesi, ivikela abantu ekushayweni kukagesi.

I-MIDA

  • Okwedlule:
  • Olandelayo:

  • Shiya Umlayezo Wakho:

    Bhala umyalezo wakho lapha futhi usithumelele wona
    • Silandele:
    • facebook
    • linkedin
    • i-twitter
    • youtube
    • i-instagram

    Shiya Umlayezo Wakho:

    Bhala umyalezo wakho lapha futhi usithumelele wona